Start with the utility service record
Begin by identifying the serving utility, service address, account or premise identifier, and the utility contact responsible for engineering questions. Collect current service correspondence, one-line diagrams, service letters, meter information and any documents that describe the point of delivery. Record the nominal voltage, phase, frequency and service arrangement as stated by the utility, but distinguish documented facts from field observations or assumptions. Note the date and source of each item; utility conditions and project records can change, and an old drawing may not reflect the installation today. Ask the utility to confirm the service point, ownership boundary, available fault-current information and any requirements for proposed modifications. Where the utility has not supplied a value, mark it as pending rather than estimating. A clear record of what is confirmed, what is observed and what still needs verification gives the engineer a dependable starting point for evaluating equipment and coordinating the next steps.
Capture available fault-current information
Available fault current is a key design input, not a value to infer from the size of existing equipment or a breaker rating. Request the utility’s available short-circuit current at the service point, along with the stated voltage, calculation basis, and date or conditions associated with the value. If the utility provides a range, maximum value or impedance data instead, preserve the original information and have a qualified electrical professional determine how it applies to the installation. Record transformer details when known, including ownership, rating, impedance and configuration; these can help clarify the system but do not replace utility confirmation. Photograph equipment nameplates only when they are safely accessible, and transcribe manufacturer, model, voltage and interrupting or withstand markings exactly. Do not open energized equipment or remove barriers to obtain data. Qualified professionals must evaluate equipment ratings, protective-device coordination and applicable code requirements against verified system conditions.
| System | Voltage, phase, current and available fault current |
|---|---|
| Configuration | Lineup, protection, controls and enclosure as specified |
| Compliance | Applicable standards and listing confirmed for the assembly |
| Delivery | California and nationwide; schedule confirmed by quote |
Describe the service configuration and distribution
Document how power enters the facility and how it is distributed downstream. Note the number and apparent arrangement of services, main disconnect locations, metering positions, transformers, switchboards or switchgear, and major feeders. Use an existing one-line diagram as a reference, then mark discrepancies discovered during a qualified site review rather than silently editing the original. Record system voltage and grounding details from reliable documents or professional verification; do not assume that similar-looking installations share the same configuration. Identify normal and alternate sources, generators, photovoltaic systems, battery storage or other interconnections that may affect operating modes and fault-current analysis. For each relevant assembly, capture nameplate data and the equipment’s physical identifier so the notes can be matched to photographs and drawings. If labels are missing, illegible or inconsistent, flag that uncertainty for investigation. These details help an engineer understand system boundaries, identify coordination questions and determine which information is needed before equipment changes can be scoped.
Record the site conditions that affect installation
Site constraints can determine whether a technically suitable design is practical to install, maintain and operate. Measure access routes, door openings, corridors, ceiling heights and turning clearances along the anticipated equipment path. Record the existing lineup’s approximate dimensions, working-space conditions, mounting surface and nearby obstructions, while leaving code and clearance determinations to qualified professionals. Note floor level changes, stairs, loading access, elevator limits and any restrictions on lifting or delivery. Document environmental conditions that may influence design review, such as indoor or outdoor exposure, moisture, dust, heat, corrosive conditions or washdown practices. Identify available wall, floor and conduit space, cable entry direction, feeder routing and known utility or structural conflicts. Photograph the equipment and surrounding area from several angles, including access points and labels, without compromising electrical safety. Include the date, location and orientation for each image. Measurements and photos are planning evidence, not substitutes for field verification before final design or installation.
Organize the record for a useful project review
Bring the information together in a concise package: a dated site summary, utility documents, available fault-current data, existing one-line drawings, nameplate transcriptions, photographs, measured access constraints and a list of unresolved questions. Label each item with its source and confidence level—for example, utility-confirmed, document-derived, observed or unverified. This prevents preliminary notes from being mistaken for design criteria. Include the intended project scope, operating priorities, anticipated loads, outage constraints and any schedule-sensitive milestones, while treating timing options as subject to project review. Share known code, specification or owner requirements for evaluation; for medium- or high-voltage equipment, identify and verify the standards applicable to that specific equipment. Ask the project engineer or equipment provider to identify missing inputs, needed utility coordination and the next safe site-review steps. A well-organized record supports a more focused technical discussion and helps teams determine what must be confirmed before equipment selection, pricing or construction planning proceeds.