MANUFACTURED IN THE USA   /   SHIPPING NATIONWIDESALES & PROJECT SUPPORT   (951) 403-5738
Gray electrical equipment with meters and breakers inside an open enclosure.
AMERICAN BUILT   /   CALIFORNIA SERVED

Busway Tap-Off Units

A tap-off unit must match more than the connected load. Coordinate its rating, protective device and interface with the busway system before specifying or ordering.

NEW SWITCHGEAR / AMERICAN COMPONENTS / BUILT TO SPEC01 — CALIFORNIA + NATIONWIDE
01
Made in the USAAmerican manufacturing
02
UL 891 switchboardsLow-voltage assemblies, as applicable
03
Short lead timesSchedule confirmed with quote
04
Nationwide shippingServing California & beyond
BUILT AROUND YOUR PROJECT / 01

Start with the Busway System

A tap-off unit is an interface between a busway run and a downstream circuit, so compatibility begins with the busway itself. Identify the manufacturer and product family, voltage and phase configuration, conductor arrangement, busway ampacity, enclosure type, and installation orientation. Include the exact catalog or identification information available from equipment documents and nameplates; visual similarity alone is not a reliable basis for selection. Systems can differ in bus configuration, contact geometry, engagement method, grounding provisions and mechanical interlocks. A unit intended for one system may not properly mate with another even when headline electrical ratings appear similar. If the existing busway documentation is incomplete, arrange for qualified personnel to verify the equipment details and interface before finalizing the design. Providing drawings, photographs of labels, and relevant installation information early helps the equipment builder identify questions while there is still time to resolve them.

Coordinate Rating with the Load

Determine the tap-off rating from the circuit design and anticipated operating conditions, not simply from the busway’s maximum rating or the load’s nameplate value. Establish system voltage, number of phases and wires, continuous and noncontinuous load, expected duty cycle, load growth, and any motor starting or other inrush characteristics. The selected unit and its protective device must be considered together with conductor ampacity, downstream equipment ratings and the available capacity of the busway. A larger device is not automatically a useful allowance for future expansion: it can affect conductor protection and coordination, and it may not be appropriate for the connected load. Conversely, a rating with too little margin can constrain operation or planned additions. Qualified electrical professionals should determine load calculations, protection and applicable code requirements for the project. Share the intended load and operating profile so the design team can evaluate the tap-off selection in context rather than treating the unit as an isolated component.

THE DETAILS THAT DRIVE THE BUILD
Project specifications to define with your quote
SystemVoltage, phase, current and available fault current
ConfigurationLineup, protection, controls and enclosure as specified
ComplianceApplicable standards and listing confirmed for the assembly
DeliveryCalifornia and nationwide; schedule confirmed by quote

Select Protection for the Circuit

The protective device is a central part of tap-off coordination. Identify whether the design calls for a circuit breaker or another permitted protective arrangement, along with the required ampere rating, pole configuration and relevant trip characteristics. Verify that interrupting capability is suitable for the available fault current at the installation point, and evaluate coordination with upstream busway protection and downstream devices. Where selective coordination, ground-fault protection, equipment protection or continuity of service is important, provide the project criteria and one-line diagram for review. These choices depend on system conditions and the complete protection scheme; a tap-off unit’s enclosure or nominal current rating does not by itself establish suitability. Also confirm whether the application requires particular operating features, such as switching or interlocking, and how those features relate to the busway interface. A qualified engineer should establish the final protective-device requirements and confirm applicable codes and standards for the installation.

Verify Physical Fit and Conditions

Electrical compatibility does not guarantee that a unit will fit the intended location. Confirm busway orientation, the permitted mounting position, available access space, adjacent equipment and the direction in which the tap-off will project. Check clearances for installation, operation and maintenance, including room to open the enclosure and reach the protective device safely. Record the busway’s physical dimensions and interface details, and note obstructions such as walls, structural members, piping or other runs. The environment matters too: identify indoor or outdoor exposure, ambient conditions, dust or moisture concerns, and any enclosure requirements specified for the site. Consider how the downstream conductors will leave the unit and route to the load without creating an impractical bend, congestion or service-access problem. Have qualified personnel verify the proposed position and installation method against equipment instructions and project requirements. Resolving these details before release can reduce field rework and avoid a unit that is electrically appropriate but impractical to install.

Prepare a Complete Submittal

A useful inquiry combines electrical, mechanical and project information. Send the busway manufacturer and series, available ratings and identification data, system voltage and configuration, requested tap-off rating, protective-device preference, load description, and one-line diagram. Include interface drawings or dimensions, mounting orientation, photographs where helpful, installation location, environmental conditions and downstream connection needs. Flag project-specific requirements for fault-current performance, coordination, switching, interlocking or future load changes so they can be reviewed rather than assumed. The builder can then clarify what is needed to evaluate the requested configuration and identify unresolved compatibility questions. For projects with schedule constraints, provide the required date and current design status early; any schedule-sensitive or expedited approach depends on project review and confirmed scope. Customers in California and elsewhere may request equipment for their projects, with shipping arrangements considered as part of the order. Before release, align the approved drawings and specifications with the actual busway system and have the responsible professionals confirm ratings, protection and installation requirements.

READY WHEN THE PROJECT IS

Let's get power moving.

From the first specification to the final shipment, start with a conversation about your project.

REQUEST A QUOTE