MANUFACTURED IN THE USA   /   SHIPPING NATIONWIDESALES & PROJECT SUPPORT   (951) 403-5738
Gray electrical switchgear cabinets with red circuit markings and breaker handles arranged on pallets.
AMERICAN BUILT   /   CALIFORNIA SERVED

Medium-Voltage Switchgear for Airports

Coordinate medium-voltage distribution with airport operating demands, transportation connections and the realities of working in restricted, active facilities.

NEW SWITCHGEAR / AMERICAN COMPONENTS / BUILT TO SPEC01 — CALIFORNIA + NATIONWIDE
01
Made in the USAAmerican manufacturing
02
UL 891 switchboardsLow-voltage assemblies, as applicable
03
Short lead timesSchedule confirmed with quote
04
Nationwide shippingServing California & beyond
BUILT AROUND YOUR PROJECT / 01

Plan feeders around terminal continuity

Airport medium-voltage feeders may supply terminal substations, baggage systems, airfield support facilities, parking structures and other essential loads. Begin by mapping each feeder from its source through switching points to the equipment it serves. Identify which loads can tolerate an interruption, which require alternate supply arrangements, and where a fault could affect multiple operating areas. This work helps establish a practical lineup and switching philosophy rather than treating switchgear as an isolated enclosure. For terminals, continuity planning should account for operating hours, passenger flows, security systems and the time needed to transfer or restore loads. Confirm normal and alternate operating configurations, including how the system behaves when a feeder or source is unavailable. Qualified electrical professionals should determine system ratings, protection and applicable code requirements. Share current one-line diagrams, load information, utility data and planned phases early so the equipment design can be evaluated against the airport’s actual distribution strategy.

Coordinate relays with the full protection scheme

Protective relays must be selected and set as part of a coordinated system, not simply matched to individual feeder equipment. Useful design inputs include available fault-current information, grounding method, transformer characteristics, upstream utility protection, downstream device data and the airport’s preferred operating modes. Engineers can use these details to assess selectivity, sensitivity, equipment duty and the consequences of different fault locations. Where alternate sources or tie breakers are involved, review whether relay logic and settings remain suitable in each permitted configuration. Also establish who will provide settings, perform studies, review logic and complete commissioning tests; these responsibilities may be shared among the engineer, owner, utility and project contractors. Any communications or monitoring interfaces should be described with their required signals, protocols and operational purpose. Avoid assuming a particular relay function or setting is appropriate without a system study. Clear responsibility and documented coordination help reduce avoidable changes during installation and support safer, more predictable operation.

THE DETAILS THAT DRIVE THE BUILD
Project specifications to define with your quote
SystemVoltage, phase, current and available fault current
ConfigurationLineup, protection, controls and enclosure as specified
ComplianceApplicable standards and listing confirmed for the assembly
DeliveryCalifornia and nationwide; schedule confirmed by quote

Define source and transportation interfaces

Airport distribution can involve utility services, on-site generation, emergency sources and connections to transportation infrastructure. Each interface brings distinct operating and protection questions. Confirm source voltage and frequency, grounding arrangement, fault contribution, metering boundaries, transfer sequence and the parties responsible for switching. If airport power connects with a rail, people-mover or other transportation system, identify ownership limits and the control, interlocking, communications and emergency procedures that govern the boundary. Document whether an interface is normally open or closed and which operating conditions permit a change in state. Utility requirements and transportation authority requirements may differ, so resolve conflicts through the project’s responsible engineers and operators before finalizing the design. Provide interface drawings, equipment data, control narratives and contact responsibilities where available. Applicable standards and codes depend on the specific medium-voltage equipment and installation; identify and verify them for the project rather than assuming that a standard used for low-voltage switchboards applies.

Design access for restricted operating areas

Airport work often takes place within secured, occupied and tightly controlled environments. Switchgear dimensions and arrangement should be reviewed alongside delivery routes, door and corridor clearances, floor loading, turning space, rigging paths and the sequence for moving equipment to its final position. Confirm whether installation access requires escorts, badging, approved work windows, security screening or coordination with airport operations. These restrictions can affect staging, tools, material handling and the time available for outages, so they belong in planning conversations before equipment configuration is fixed. In operating electrical rooms, verify working clearances, cable entry routes, ventilation, environmental conditions and the space needed for inspection or component replacement. Coordinate with facility staff to understand noise, dust-control and fire-protection requirements. Existing conditions should be checked in the field, especially where drawings may not reflect later modifications. Early access planning helps identify constructability conflicts while there is still room to adjust the equipment layout or installation sequence.

Prepare a review-ready project package

A useful inquiry package lets the manufacturer and project team evaluate design fit without relying on assumptions. Include the latest one-line diagram, system voltage, bus and feeder arrangement, source details, fault-current data, grounding information, relay and metering requirements, cable entry preferences and the relevant environmental conditions. Add installation drawings or room measurements, delivery constraints, access rules, outage windows and a description of terminal or transportation interfaces. Distinguish firm requirements from items still under engineering review, and identify the engineer of record, utility contacts and airport stakeholders who will approve interfaces. For schedule-sensitive work, describe required milestones and constraints so options can be reviewed against project conditions; timing and feasibility remain subject to review. As an American builder of new switchgear using American components, Switchgear Builder California supplies equipment to customers in California and nationwide. Discuss the project’s applicable standards, ratings and documentation directly with qualified professionals, who determine protection and code requirements for the installation.

READY WHEN THE PROJECT IS

Let's get power moving.

From the first specification to the final shipment, start with a conversation about your project.